Fire ratings for panels: Class A and B-s1,d0

Fire is the grade most often claimed and least often documented in wall panel conversations. A class is never a property of a family name or a feel of a material; it is the result of a laboratory test on a specific build-up, reported under a named framework - ASTM E84 in North America, EN 13501-1 in Europe, GB 8624 in China. This note explains what each framework measures, how to read the codes, and how the class travels into an order file. The full reference sits in the fire rating guide.

Fire ratings for panels: Class A and B-s1,d0 - Performance and specs

What a fire class actually certifies

A fire class describes how a tested assembly behaved in a defined laboratory method: how flames spread across its surface, how much smoke it developed, whether it produced flaming droplets. The certificate belongs to the assembly that was tested - the panel at a stated thickness, with its stated face, adhesive, core and, on acoustic families, its felt backing and mounting. Decorative wall panels are usually classified as part of such an assembly rather than as a bare board, because on a wall they behave as a system. Two consequences follow. First, a class claimed for a family is meaningless until it is tied to a build-up. Second, any change of layer - a different felt, a different adhesive, a different thickness - is a different product in the eyes of the test, and the honest paperwork follows the change.

No decorative wood panel is fireproof, and the desk does not use the word. What exists is a range of documented classes, and the buyer task is to match the class the project names to a report that describes the panel actually being shipped.

ASTM E84: Class A, B and C

North American practice reads surface burning behavior from the ASTM E84 tunnel test, which reports a Flame Spread Index and a Smoke Developed Index. The published class definitions are widely used in specifications: Class A covers a Flame Spread Index of 0 to 25, Class B covers 26 to 75 and Class C covers 76 to 200, each with a Smoke Developed Index not more than 450. Interior wall finishes in many US project specifications are called out as Class A, which is why the phrase appears so often in panel listings - and why it should always arrive attached to the words per test report, naming the assembly tested. The ASTM E84 explainer describes the test method from a buyer perspective.

A practical caution: a report written for a plain board does not silently extend to the same board with a felt backing bonded to it. When a project consultant asks for Class A on an acoustic slat wall, the desk asks the partner plant for the report on the slat assembly with felt, or arranges testing for the exact build-up the project will install.

EN 13501-1: reading B-s1,d0

European projects read reaction to fire through EN 13501-1, which compresses three judgments into one code. The first letter grades contribution to fire; the s suffix grades smoke production, where s1 is the better end of the scale; the d suffix grades flaming droplets, where d0 means none observed within the test conditions. A wood panel line commonly specified as B-s1,d0 is therefore a panel whose tested build-up reached European class B for contribution to fire, with low smoke and no flaming droplets per the report. The suffixes matter as much as the letter: two panels both reaching B can differ sharply on smoke, and smoke is what corridor specifications care about. The EN 13501-1 note decodes the full family of classes and suffixes.

Unlike a single-index system, the European code cannot be inferred from one number. Classification reports describe the product, the end-use condition and the mounting, and they are issued by notified bodies within the European system, where EN 13986 provides the harmonized route for wood-based panels. The desk requests the classification report, not a summary sentence in a quotation.

GB 8624 and third frameworks

The Chinese system classifies building materials under GB 8624, a framework whose letter structure is broadly legible to readers of the European classes, and it is the vocabulary domestic projects and many Asian specifications use. A buyer working across markets should resist the temptation to translate between frameworks: a Class A result in the tunnel test and a B-s1,d0 classification come from different methods and describe different behaviors, and one is not a conversion of the other. Where a program serves several regions, the clean answer is testing per framework for the build-up in question, arranged once and referenced by every order that follows.

FrameworkWhat it measuresCommon reading in specificationsWhat the buyer requests
ASTM E84Surface burning: flame spread and smoke developed in the tunnel testClass A (0-25), Class B (26-75), Class C (76-200), smoke index not more than 450The test report for the exact build-up, per report
EN 13501-1Reaction to fire with smoke and droplet suffixesCodes such as B-s1,d0 for wood panel assembliesClassification report naming product and mounting
GB 8624Chinese classification of building material burning behaviorGrades named per project specificationCertificate per lot matching the specified grade

Why the build-up matters more than the family name

Nothing on a panel contributes nothing to the test. The veneer or laminate face, the adhesive line, the core, the felt and even the cavity behind an acoustic panel are all part of what burned in the laboratory, which is why two panels of the same silhouette can sit in different classes. Hospitality buyers meet this most directly: hotel corridor and public-area specifications name a framework, a class and often a smoke suffix, and the consultant checks the report against the installed system, not against the catalog photograph. The hospitality projects page shows how the requirement is handled at program level, with the fire file attached to the room package from sample approval onward.

Putting the grade into the order

Three lines close the fire conversation in an order file. The framework and class the project requires, written as the specification names it. The report reference that matches the build-up, including felt and mounting where present, held by the plant and verified per project. And the claim language for the listing - the class stated per test report, with no broader promise than the report supports. Emission and fire paperwork travel together in the desk document pack, alongside the certificates described on the compliance page. Reference quantities and schedules stay as ranges confirmed in writing per order, as set out on the MOQ and lead time page, and a program with a named fire class can be started through the quote form, with the class fixed before samples are produced.

Questions buyers ask

Is a Class A panel fireproof?

No panel line is described as fireproof in this catalogue. A Class A result means the tested build-up met the ASTM E84 surface burning thresholds in the report; it is a documented class, not an absence of fire behavior.

Does the felt backing change the fire class?

It can, because the felt is part of the tested assembly. A report written for a bare panel does not automatically cover the panel with felt bonded to it, so the report must match the build-up being quoted.

Can a US Class A result be converted to a European class?

No. The frameworks test differently and report different behaviors. Where a program serves several regions, testing per framework for the same build-up is the clean route, arranged once and referenced by later orders.

What do hospitality projects usually ask for?

A named framework and class with any smoke suffix, plus the classification or test report for the installed assembly. The consultant checks the report against the system, so the desk attaches the fire file to the room package from sample approval.

Who keeps the fire report?

The partner plant and the testing body hold the original documents; Grainelle verifies the report per project and files the reference with the order documents so the listing can be defended on request.

Send the lines and colors you need, target sizes and grades, the area per color and your market. The desk replies in writing with matched plants, a swatch program, certification routes and the reference MOQ.